HOME > 공학 > 환경공학 > 한국환경관리학회 > 환경관리학회지
다중이용시설의 라돈농도 분포 및 특성 연구 - 천안시를 중심으로
분야 공학 > 환경공학
저자 이택중 정명상 김흥락 박혜숙
발행기관 한국환경관리학회
간행물정보 환경관리학회지 2010년, 환경관리학회지 第16卷 第1號, 1page~9page(총9page)
파일형식 1805225 [다운로드 무료 PDF 뷰어]
판매가격 6,000원
적립금 180원 (구매자료 3% 적립)
이 자료를
논문의 미리보기 2페이지를 PDF파일로 제공합니다.
 
연관 논문
다중이용시설 내 공기청정기 사용으로 인한 실내 미세먼지 위해 저감 평가
기기 중성자방사화 분석을 이용한 대전 지하철 객차 내 PM10과 미량성분의 특성 -
구두발표 : 영동지역 단층대 주변 지하수 중 우라늄 및 라돈-222 산출특성
도시지역 토지이용에 따른 비점오염물질의 초기강우 유출특성 분석
주요 지질별 지하수 개발·이용 특성 및 수질 관리실태 비교연구
 
 
목차
부제 : A study on the concentration distribution and characteristic of Radon for Public facilities in Cheonan area
Abstract
1. 서론
2. 조사대상 및 측정방법
3. 결과 및 고찰
4. 결론
참고문헌
 
 
영문초록
For studying on concentration distribution and characteristic of radon for public facilities, we analyzed radon from 13 hospitals, 8 large stores, 8 fomentation rooms, 5 nurseries, 5 indoor parking lots, 2 postpartum clinics, 1 underground shopping center from January to December in Cheonan area. The results were as follow
1. Indoor average radon concentrations investigated were 0.73 pCi/L in underground shopping center. That value was highest one. and other average radon concentrations were 0.42 pCi/L in fomentation room, 0.34 pCi/L indoor parking lot, 0.32 pCi/L in nursery, 0.28 pCi/L in large store and postpartum clinic, 0.25 in hospital. Indoor average radon concentration of public facilities were 0.37 pCi/L, it was lower than 4.0 pCi/L of recommended criterion.
2. Investigating the distribution of concentration in underground facilities and above ground, the average radon concentration in underground facilities was 0.38 pCi/L that was higher than 0.17 pCi/L in above ground. The ratio of underground concentration to above ground in hospital was 1.0, so there was no significant difference between underground and above ground. But there was significant difference between indoor parking lot and large store as 4.0 and 2.8.
3. Investigating the time variation with radon concentration for a day, average radon concentration for a day in large store and hospital were 0.28 pCi/L, 0.63 pCi/L respectively. The difference with radon concentration for a day was 0.7 pCi/L in large store and 1.10 pCi/L in hospital. in Respect of ventilation system, The average concentration in large shopping center was 0.18 pCi/L with ventilation working, 0.38 pCi/L without ventilation working and in hospital 0.53 pCi/L, 0.72 pCi/L. This showed that radon concentration accumulated in a hermetic chamber without ventilation were high. There fore the ventilation was considered as a main means of indoor radon reduction.
4. When anticipating each facility worker"s annual effective dose by the inhalation in public facilities that the mean concentration was 0.37 pCi/L, annual effective dose was 13.54 mRem/yr. And underground shopping center has the highest value as 26.71 mRem/yr. This is much lower than 130 mRem/yr(1.3 mSv/yr) which is worldwide annual effect dose by The inhalation of radon and Its daughter announced in International Commission on Radiological Protection(ICRP).
In conclusion, The Radon average concentration public facilities in Cheonan was lower than that of recommended indoor criterion and annual effective dose was lower than that of ICRP, But considering a main cause of lung cancer and increase of living in indoors and an area with much Radon in soil, The investigation of regional Radon condition, research on health effect of Radon, the measure of Radon reduction must be needed to carry out.
 
 
radon, public facilities, Cheonan area
 
 
도움말
본 논문은 참고용 논문으로 수정 및 텍스트 복사가 되지 않습니다.
 
 
추천자료
실내공기질(IAQ) 관리 및 국내, 외 대응현황 이해 및 고찰
환경보건학연구방법3B)작업환경유해인자실내환경실내오염건강상장애근골격계질환화학물질중독등분야0
[환경공학] 주거 건물의 실내공기 오염실태와 개선방안
원자력산업의 문제와 추진과제00
[화학] 방사선장해방호
[감성디자인공학] 카펫 및 러그제품의 환경기능성 평가방법의 표준화
[주거환경] 친환경 건강주거
새집 증후군 레포트
[환경] 새집증후군의 실태와 해결방안
[생활과학] 지하철 오염의 문제점과 대책방안oe
오늘 본 자료
오늘 본 자료가 없습니다.
장바구니 담은 자료
장바구니가 비어 있습니다.
이 간행물 인기자료
피혁제조공정에서의 발생폐수 특성 -
고정층 반응기를 이용한 건식배연 탈...
사전환경성검토제도에 대한 설문조사 ...
여수의 환경변화에 따른 귀화식물상과...
염색폐수에 포함된 색도와 유기물의 ...
이 간행물 신규자료
섬유 보강콘크리트 보의 강도특성에 ...
상수도 관로 노화에 관한 조사연구 -
설계강우강도 적용에 따른 노면배수시...
소규모 농업용저수지의 노후화에 따른...
하천횡단구조물 배치에 따른 2차원 수...
저작권 정보
본 학술논문은 ㈜누리미디어와 각 학회간에 저작권 계약이 체결된 것으로 HAPPY학술이 제공하고 있습니다. 본 저작물을 불법적으로 이용시는 법적인 제재가 가해질 수 있습니다.
 
서비스이용약관 | 개인정보취급방침 | E-mail 수집 거부 | 제휴 및 광고문의 | FAQ
이메일 무단 수집 거부
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나 그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며, 이를 위반시 정보통신망법에 의해 형사처벌됨을 유념하시기 바랍니다. [게시일 2003년 4월 2일]