HOME > 공학 > 기타(공학) > 한국생태환경건축학회 > 한국생태환경건축학회 논문집
The Evaluation of Energy Efficiency of Apartment Units after Conversion of Balconies into an Integrated Part of Interior Living Space by Computing with ECO2 Software -
분야 공학 > 기타(공학)
저자 Kim, Chang-Sung
발행기관 한국생태환경건축학회
간행물정보 한국생태환경건축학회 논문집 2016년, 한국생태환경건축학회 논문집 제16권 제2호, 11page~16page(총6page)
파일형식 2952020 [다운로드 무료 PDF 뷰어]
판매가격 6,000원
적립금 180원 (구매자료 3% 적립)
이 자료를
논문의 미리보기 2페이지를 PDF파일로 제공합니다.
 
연관 논문
Patten Language를 이용한 계단실형 공동주택의 남쪽 진입형 현관 방식 제안 ( Some Suggestions for the Design and Use of Balconies and their Adjacent Spaces in the Apartment Housing through the application of Alexander`s principle ) -
Effect of Guide Vane on the Performance of Impulse Turbine for Wave Energy Conversion -
신축 아파트 단위세대의 규모에 따른 인테리어 거주후평가(Interior-POE)에 관한 연구 -
The Transient Conjugate Heat Transfer Analysis in Multi-zone of an Apartment House by using Crank-Nicolson Finite Difference Method (FDM) -
Performance Analysis of a savonius type direct drive turbine for wave energy conversion -
 
 
목차
부제 :
ABSTRACT
1. Introduction
2. Current State of Building Energy Efficiency Rating Certificate and Characteristics of ECO2 Software
3. Evaluation Model Set-up
4. Energy Performance Evaluation for Input Models
5. Conclusions
References
 
 
영문초록
Purpose: International efforts to save Earth’s environment against global warming and environmental pollution have been made in many countries. Energy consumption of buildings has been continuously increasing, and it has been over 40% of total energy consumption in the world. Energy consumption of buildings in Korea reaches 24% of total energy consumption. So, Korea government has executed building energy rating systems to control energy consumption of buildings. Method: This study was carried out to evaluate the energy performance of apartment unit plans according to converting balconies into living areas. For the study, six types of input models were made. Two input models(SP1 and SP 2) were the standard units that balcony areas were not converted into living areas, and four ones(EP 1, EP 2, EP 3 and EP 4) were the extended unit plans that balcony areas were turned into living areas. All of them were simulated with ECO2 software to assess building energy efficiency. Result: According to the results, the energy performance of the EP 2 and EP 4 models were 21. 8% higher than SP 1 model and 9.2% higher than SP 2 model.
 
 
에코 2, 프로그램, 공동주택, 발코니, 에너지 효율, ECO2 Software, Collective Housing, Balcony, Energy Efficiency
 
 
도움말
본 논문은 참고용 논문으로 수정 및 텍스트 복사가 되지 않습니다.
 
 
추천자료
[교양] 정보 인프라 관련 미국정부 논문
[지리] GIS FAQ입니다.
물리전자_솔루션 KASSAP 최신판
[컴공]네트웍과 NT에 관한 자료입니다.
[[솔루션]] :: Lehninger Biochemistry 5edition[the foundations of Biochemistry]
열역학 솔루션(Thermodynamics: An Engineering Approach)7판
TOEIC RC Part 7 레포트
[토익] 해커스 토익 예상문제(3년치분)
토익 기출어휘(숙어) 대탐험[1]
할리데이 일반물리학 9판 솔루션
오늘 본 자료
오늘 본 자료가 없습니다.
장바구니 담은 자료
장바구니가 비어 있습니다.
이 간행물 인기자료
Analysis of the Efficient Utilizati...
베네시안 블라인드가 적용된 오피스 ...
신년사 -
미세 다공질 광물과 아미드계 분해제...
실물대 모형을 이용한 고령자 주거공...
이 간행물 신규자료
일본 쉐어가나자와 마을내 고령자주택...
다중주택의 외부 환경 실태조사 분석 ...
초 · 중 · 고등학교 재난안전 평가...
녹색커뮤니티 계획요소와 도시재생 사...
용도별 공공건축물의 한옥 구성요소 ...
저작권 정보
본 학술논문은 ㈜누리미디어와 각 학회간에 저작권 계약이 체결된 것으로 HAPPY학술이 제공하고 있습니다. 본 저작물을 불법적으로 이용시는 법적인 제재가 가해질 수 있습니다.
 
서비스이용약관 | 개인정보취급방침 | E-mail 수집 거부 | 제휴 및 광고문의 | FAQ
이메일 무단 수집 거부
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나 그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며, 이를 위반시 정보통신망법에 의해 형사처벌됨을 유념하시기 바랍니다. [게시일 2003년 4월 2일]