HOME > 의약학 > 정형외과학 > 대한고관절학회 > Hip & Pelvis(구 대한고관절학회지)
Results of Primary Total Hip Arthroplasty Using 36 mm Femoral Heads on 1st Generation Highly Cross Linked Polyethylene in Patients 50 Years and Less with Minimum Five Year Follow-up
분야 의약학 > 정형외과학
저자 ( Won Kee Choi ) , ( Myung Rae Cho ) , ( Hee Soo Kim ) , ( Jun Ho Nam ) , ( Seung Bum Chae )
발행기관 대한고관절학회
간행물정보 Hip & Pelvis(구 대한고관절학회지) 2016년, 제28권 제2호, 76~81쪽(총6쪽)
파일형식 36201358.pdf [다운로드 무료 PDF 뷰어]
판매가격 4,000원
적립금 120원 (구매자료 3% 적립)
이 자료를
논문의 미리보기 2페이지를 PDF파일로 제공합니다.
 
연관 논문
Original Articles : Results of Primary Total Hip Arthroplasty with 36-mm Femoral Heads on Highly Cross-linked Polyethylene-Minimum Seven-years Follow-up
ORIGINAL ARTICLE : Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner
Bencox® Hip Stem을 이용한 인공 고관절 치환술의 최소 5년 추시 결과 -
Harris-Galante 비구컵에서 발생한 Polyethylene Liner 분리 - 분리에 영향을 준 요인에 관한 대조 연구 - ( Dissociation of Polyethylene Liner after Total Hip Arthroplasty Using Harris-Galante Porous Acetabular Components - A comparative study of the factors that influence on the dissoc
Original Articles : Total Hip Arthroplasty in Patient with Aplastic Anemia
 
 
영문초록
Purpose: We evaluated the clinical and radiographic midterm results of primary total hip arthroplasty (THA) using a 36 mm diameter femoral head on 1st generation highly cross-linked polyethylene (HXLPE) in patients 50 years and less with minimum five year follow-up. Materials and Methods: We retrospectively reviewed 31 patients (41 hips) aged 50 years and less underwent primary THA with a 36 mm diameter femoral head on HXLPE between 2004 and 2010. Clinical follow-ups included specific measurements like modified Harris hip scores (HHS) and Merle d`Aubigne and Postel score. For radiologic evaluations, together with position of acetabular cup at six weeks later of postoperation, we separately calculated the penentrations of femoral head into polyethylene liners during postoperation and one year later check-ups, and during one year later check-ups and final check-ups. Results: There were no major complications except for one case of dislocation. Average modified HHS at final follow-up was 88 (81-98), and Merle d`Aubigne and Postel scores were more than 15. Mean acetabular cup inclination and anteversion were 45.81。(36.33。-54.91。) and 13.26。(6.72。-27.71。), respectively. Average femoral head penetration of steady-state wear rate determined using radiographs taken at one-year postoperatively and at latest follow-up was 0.042±0.001 mm/year. Conclusion: Based on minimum 5 years clinical results, we think 36 mm metal head coupling with HXLPE as the good alternate articulation surface when planning THA for patients aged 50 years and less.
 
 
Total hip arthroplasty, 36 mm femoral head, Highly cross-linked polyethylene
 
 
도움말
본 논문은 참고용 논문으로 수정 및 텍스트 복사가 되지 않습니다.
 
 
추천자료
[의학과][응급의학과] 정형외과 사례(52세 남성환자)
[교양] 정보 인프라 관련 미국정부 논문
물리전자_솔루션 KASSAP 최신판
미국 장애학생 전환교육의 실제와 과제
[[솔루션]] :: Lehninger Biochemistry 5edition[the foundations of Biochemistry]
[의학] 인공관절
Stent의 정의 및 종류와 재료, 시술과정
3D printing 레포트
[토익공략법]토익 390점에서 870점 올리기 완결판(LC, RC 포함)
[식품저장학] Food Irradiation Technology(방사선살균기술)
오늘 본 자료
오늘 본 자료가 없습니다.
장바구니 담은 자료
장바구니가 비어 있습니다.
이 간행물 인기자료
천미골부에 발생한 척색종 (Chordoma ...
비구골절(Acetabular Fracture)의 분...
고령의 전자간부 골에서 시행한 시멘...
고관절주위 종양에 대한 임상적 고찰 ...
보존적 요법으로 치료한 Legg-Calve-P...
이 간행물 신규자료
Management of Blood Loss in Hip Art...
Dissociation of Polyethylene Liner ...
Measuring the Impact of Femoral Hea...
Pelvic Insufficiency Fracture in Se...
Radiographic Outcomes of Osteosynth...
저작권 정보
본 학술논문은 한국학술정보㈜ 각 학회간에 저작권 계약이 체결된 것으로 HAPPY학술이 제공하고 있습니다. 본 저작물을 불법적으로 이용시는 법적인 제재가 가해질 수 있습니다.
 
서비스이용약관 | 개인정보취급방침 | E-mail 수집 거부 | 제휴 및 광고문의 | FAQ
이메일 무단 수집 거부
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나 그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며, 이를 위반시 정보통신망법에 의해 형사처벌됨을 유념하시기 바랍니다. [게시일 2003년 4월 2일]