Repair and strengthening is necessary to extend the service life of existing buildings. Polymer-modified cement mortar (PCM) has been extensively used as a high performance material particularly for finishing and repairing works in concrete building because of itsexcellent adhesion, waterproofing, resistance to chemical attack, and workability. As PCM contains organic polymer, it is necessary to clarify its properties at high temperature under fire, on which sufficient data are not available. This paper evaluated the burn-up characteristics of polymer-modified cement mortar with cone calorimeter test, non-combustibility test and flammability test with experimental parameters such as the types of polymer, unit-polymer content, polymer-cement ratio and thickness of the specimen.
 
 
폴리머 시멘트 모르타르, 발열성 시험, 불연성 시험, 총발열량, 단위 폴리머량, 시험체 두께, polymer-modified cement mortar, non-combustibility test, flammability test, total heat release, unit-polymer content, thickness of the specimen
 
다운로드 2s903147.pdf